使用 S7-1500 顺序屏蔽光幕





- 0
- 271
- 1227
Access to the assembly cell is to be protected with a safety light curtain. The objective is to detect in case of a violation of the detection zone (interruption of light curtain) if a workpiece is transported through the light curtain or if it was interrupted by another object.
Solution
So-called “muting” is used to distinguish if the protective field is violated by the transport of workpieces or by other reasons. Muting is the intentional suppression of the protective function of light curtains
- the light curtain is “muted” temporarily. For this purpose, muting sensors are installed on both sides of the light curtain which determine in which cases to activate muting. This allows transporting workpieces out of the work area without interrupting the production flow and at the same time monitoring access to the hazard area.
Fig. 1
Figure 2 schematically shows the most important components of the application example:
- SIMATIC F-CPU (IO controller)
- Distributed I/O SIMATIC ET 200SP (IO device) with DI, DQ, F-DI, F-DQ
- SICK safety light curtain
- SICK photoelectric retro-reflective sensors as muting sensors
Fig. 2- Sequential muting with 4 muting sensors (2 sensor pairs) is implemented in the application example. Photoelectric retro-reflective sensors are used as muting sensors.
Documentation and example project
Example project for TIA Portal V13 SP1 (18,3 MB)
Library "LMutS" V2.0.1 for TIA Portal V13 SP1 (1,4 MB)
Last Changes
Bug fix on output "freeReq"
Additional Keywords
Safety Advanced, light curtain
https://support.industry.siemens.com/cs/cn/zh/view/58793869
- 评论

- 为什么OPC UA客户端不能按照STEP 7 (TIA Portal)中定义的顺序接收数据?
- 如何进行故障屏蔽?
- 电缆的屏蔽与接地
- 哪些SINAMICS 驱动器可以在SIMATIC S7-1500(T)控制器的运动控制功能中使用
- 使用 S7-1500 和 S7-1200 做 OPC UA 服务器有那些系统限制?
- 使用 S7-1500 进行用户程序诊断
- 如何使用 TCON 通信指令编程建立两个 S7-1500 CPU 之间的开放式用户通信?
- 故障安全控制器 S7-1200 和 S7-1500 使用组态控制(选件处理)时要注意什么?
- S7-1500 CPU 使用"Modbus_Master", "Modbus_Slave" 和 "Modbus_Comm_Load"指 令的注意事项
- 使用 STEP 7 (TIA Portal) V12 对 S7-1200 和 S7-1500 编程的推荐条目

隐私政策更新提示
欢迎您来到西门子数字化工业支持中心网站!我们使用cookies来确保您能最好地使用我们的网站,进行网站分析并根据您的兴趣定制内容。我们有时会与第三方共享cookie数据。继续浏览本网站,即表示您同意我们使用cookies。您亦可以参考西门子数据隐私政策以了解更多相关信息。
扫码分享